This work was partially funded by the Spanish Government Research grant M. C. T. CLIMABCAR project DPI 2003-01567, the MINICON project (FIT 0204-2004-68 and FIT 020100-2003-233) and the SACSCC project (ENE 2007-63965). Their contributions are greatly appreciated. The authors also express a special acknowledgement to the laboratory technicians Mr. Manuel Santos and Mr. Carlos Cobos for their help with the solar facility setup and maintenance.
Anàlisi d'autories institucional
Rodriguez-Hidalgo, M. C.Autor o coautorInstantaneous performance of solar collectors for domestic hot water, heating and cooling applications
Publicat a:Energy And Buildings. 45 152-160 - 2012-02-01 45(), DOI: 10.1016/j.enbuild.2011.10.060
Autors: Rodriguez-Hidalgo, M. C.; Rodriguez-Aumente, P. A.; Lecuona, A.; Nogueira, J.;
Afiliacions
Resum
This study has been carried out with a building experimental solar facility based on a 9-year-old field of 50 m(2) flat plate solar collectors located south of Madrid, Spain. Building domestic hot water production and heating and cooling applications were implemented in the facility. Experimental data corresponding to 100 operating variables (mainly temperatures and flow rates) were recorded during an entire year at intervals of 10 min, and from this data, all of the relevant performance parameters were derived. Three thermocouples measured the centre point instantaneous temperatures of the glass cover, the box back surface and the absorber plate of one of the collectors. A 1D collector transient model, based on thermal resistances and capacitances, has been developed and validated with the experimental database. Both experimental and modelled collector thermal energy output and outlet temperatures were obtained under instantaneous real operating conditions. The individual effect on the drop of the thermal energy output can be summarised in the following yearly averaged values: 15.0% due to collector surface aging, 15.7% due to thermal loss produced by wind velocity magnitude and direction, +/- 3.2% variations due to thermal capacitance and 7.6% due to incident angle of irradiance. Finally, the repercussions on the performance of the real applications are discussed. (C) 2011 Elsevier B.V. All rights reserved.
Paraules clau
Indicis de qualitat
Impacte bibliomètric. Anàlisi de la contribució i canal de difusió
El treball ha estat publicat a la revista Energy And Buildings a causa de la seva progressió i el bon impacte que ha aconseguit en els últims anys, segons l'agència WoS (JCR), s'ha convertit en una referència en el seu camp. A l'any de publicació del treball, 2012, es trobava a la posició 7/122, aconseguint així situar-se com a revista Q1 (Primer Cuartil), en la categoria Engineering, Civil.
Des d'una perspectiva relativa, i atenent a l'indicador de impacte normalitzat calculat a partir del Field Citation Ratio (FCR) de la font Dimensions, proporciona un valor de: 7.64, el que indica que, comparat amb treballs en la mateixa disciplina i en el mateix any de publicació, el situa com un treball citat per sobre de la mitjana. (font consultada: Dimensions Jul 2025)
Concretament, i atenent a les diferents agències d'indexació, aquest treball ha acumulat, fins a la data 2025-07-10, el següent nombre de cites:
- WoS: 19
- Scopus: 20
Impacte i visibilitat social
Anàlisi del lideratge dels autors institucionals
Hi ha un lideratge significatiu, ja que alguns dels autors pertanyents a la institució apareixen com a primer o últim signant, es pot apreciar en el detall: Primer Autor (RODRIGUEZ HIDALGO, MARIA DEL CARMEN) .