Cobo, AntonioAuthorVillalba-Mora, ElenaCorresponding AuthorFerré, XavierAuthorEscalante, WalterAuthorMoral, CristianAuthorAutomatic and Real-Time Computation of the 30-Seconds Chair-Stand Test without Professional Supervision for Community-Dwelling Older Adults
Publicated to:Sensors. 20 (20): 1-24 - 2020-10-01 20(20), DOI: 10.3390/s20205813
Authors: Cobo, Antonio; Villalba-Mora, Elena; Perez-Rodriguez, Rodrigo; Ferre, Xavier; Escalante, Walter; Moral, Cristian; Rodriguez-Manas, Leocadio
Affiliations
Abstract
The present paper describes a system for older people to self-administer the 30-s chair stand test (CST) at home without supervision. The system comprises a low-cost sensor to count sit-to-stand (SiSt) transitions, and an Android application to guide older people through the procedure. Two observational studies were conducted to test (i) the sensor in a supervised environment (n = 7; m = 83.29 years old, sd = 4.19; 5 female), and (ii) the complete system in an unsupervised one (n = 7; age 64-74 years old; 3 female). The participants in the supervised test were asked to perform a 30-s CST with the sensor, while a member of the research team manually counted valid transitions. Automatic and manual counts were perfectly correlated (Pearson's r = 1, p = 0.00). Even though the sample was small, none of the signals around the critical score were affected by harmful noise; p (harmless noise) = 1, 95% CI = (0.98, 1). The participants in the unsupervised test used the system in their homes for a month. None of them dropped out, and they reported it to be easy to use, comfortable, and easy to understand. Thus, the system is suitable to be used by older adults in their homes without professional supervision.
Keywords
Quality index
Bibliometric impact. Analysis of the contribution and dissemination channel
The work has been published in the journal Sensors due to its progression and the good impact it has achieved in recent years, according to the agency WoS (JCR), it has become a reference in its field. In the year of publication of the work, 2020, it was in position 14/64, thus managing to position itself as a Q1 (Primer Cuartil), in the category Instruments & Instrumentation.
From a relative perspective, and based on the normalized impact indicator calculated from the Field Citation Ratio (FCR) of the Dimensions source, it yields a value of: 3.52, which indicates that, compared to works in the same discipline and in the same year of publication, it ranks as a work cited above average. (source consulted: Dimensions Jun 2025)
Specifically, and according to different indexing agencies, this work has accumulated citations as of 2025-06-01, the following number of citations:
- WoS: 12
- Scopus: 14
- Europe PMC: 8
- Google Scholar: 21
- OpenCitations: 12
Impact and social visibility
Leadership analysis of institutional authors
There is a significant leadership presence as some of the institution’s authors appear as the first or last signer, detailed as follows: First Author (Cobo Sánchez de Rojas, Antonio) .
the author responsible for correspondence tasks has been VILLALBA MORA, ELENA.