Influence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo study

Publicado en: Journal Of Dentistry. 115 103851- - 2021-12-01 115(), DOI: 10.1016/j.jdent.2021.103851

Autores:

Revilla-Leon, Marta; Quesada-Olmo, Nieves; Gomez-Polo, Miguel; Sicilia, Elena; Farjas-Abadia, Mercedes; Kois, John C.;
[+]

Afiliaciones

Kois Ctr, Seattle, WA USA - Autor o Coautor
Revilla Res Ctr, Madrid, Spain - Autor o Coautor
SEMEPRO: Seguridad y Mejora de Procesos. Universidad Politécnica de Madrid - Autor o Coautor
Texas A&M Univ, Coll Dent, Comprehens Dent Dept, AEGD Residency, Dallas, TX USA - Autor o Coautor
Tufts Univ, Prosthodont, Dept Prosthodont, Sch Dent Med, Boston, MA 02111 USA - Autor o Coautor
Univ Complutense Madrid, Dept Conservat Dent & Prosthodont, Sch Dent, Madrid, Spain - Autor o Coautor
Univ Politecn Madrid, Dept Topog Engn & Cartog, Madrid, Spain - Autor o Coautor
Univ Politecn Valencia, Dept Geodesy Mapping & Surveying Engn, Valencia, Spain - Autor o Coautor
Univ Washington, Grad Prosthodont, Dept Restorat Dent, Seattle, WA 98195 USA - Autor o Coautor
Ver más

Resumen

Objectives: To evaluate whether the cutting-off and rescanning procedures have an impact on the accuracy (trueness and precision) of the intraoral digital scan. Methods: A right quadrant digital scan (reference scan) of a participant was obtained using an intraoral scanner (IOS) (TRIOS 4; 3Shape A/S, Copenhagen, Denmark). The reference scan was duplicated 135 times and divided into 3 groups based on the number of rescanned mesh areas: 1 (G1 group), 2 (G2 group), and 3 (G3 group) mesh holes. Each group was subdivided into 3 subgroups depending on the mesh hole diameter: 2 mm- (G1-2, G2-2, and G3-2), 4 mm- (G1-4, G2-4, and G3-4), and 6 mm- (G1-6, G2-6, and G3-6) (n = 15). A software program (Geomagic; 3D Systems, Rock Hill, SC, USA) was used to assess the discrepancy between the reference and the experimental scans using the root mean square (RMS). Kruskal-Wallis and post hoc multiple comparison Dunn's tests were used to analyze the data (alpha=0.05). Results: Trueness ranged from 5 to 20 mu m and precision ranged from 2 to 10 mu m. For trueness assessment, KruskalWallis test revealed significant differences on the RMS error values among the groups tested (P<.05). The G3-6 group obtained the lowest trueness and lowest precision values, while the G1-2, G1-4, G2-2, G2-4, and G3-2 groups computed the highest trueness and precision values. When comparing groups with the same number of rescanned mesh holes but with different diameter, the higher the diameter of the rescanned mesh hole, the lower the trueness values computed; however, when comparing groups with the same diameter of the rescanned mesh hole but with differing number of rescanned mesh holes, no significant differences were found in the RMS values among the groups. For the precision evaluation, Levene's test showed a lack of equality of the variances, and therefore of the standard deviations. The F-test with Bonferroni correction identified significant differences between the SDs between group G3-6 and all the other groups. When comparing instead the interquartile range (IQRs) due to the non-normality of the data, groups G1 and G2 also showed lower IQR values or higher precision than groups G3. Conclusions: Cutting-off and rescanning procedures decreased the accuracy of the IOS tested. The higher the number and diameter of the rescanned areas, the lower the accuracy. Clinical significance: Cutting-off and rescanning procedures should be minimized in order to increase the accuracy of the IOS evaluated. The intended clinical use of the intraoral digital scan is a critical factor that might determine the scanning workflow procedures.
[+]

Palabras clave

AccuracyAdultArticleClinical articleComputer aided designComputer-aided designDenmarkDental impressionDental impression techniqueDigital scanExecutionFemaleFixed prosthodonticsHumanHumansImaging, three-dimensionalImplant impressionsIn vivo studyIntraoral scannerKruskal wallis testMaleMesh holeModels, dentalPrecisionRescanning proceduresSoftwareSurgical meshThree-dimensional imagingWorkflow

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista Journal Of Dentistry debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia WoS (JCR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2021, se encontraba en la posición 11/92, consiguiendo con ello situarse como revista Q1 (Primer Cuartil), en la categoría Dentistry, Oral Surgery & Medicine.

Desde una perspectiva relativa, y atendiendo al indicador del impacto normalizado calculado a partir de las Citas Mundiales de Scopus Elsevier, arroja un valor para la media Ponderada del Impacto Normalizado de la agencia Scopus: 13.26, lo que indica que, de manera comparada con trabajos en la misma disciplina y en el mismo año de publicación, lo ubica como trabajo citado por encima de la media. (fuente consultada: ESI 13 Nov 2025)

De manera concreta y atendiendo a las diferentes agencias de indexación, el trabajo ha acumulado, hasta la fecha 2025-12-22, el siguiente número de citas:

  • WoS: 7
  • Scopus: 61
[+]

Impacto y visibilidad social

Desde la dimensión de Influencia o adopción social, y tomando como base las métricas asociadas a las menciones e interacciones proporcionadas por agencias especializadas en el cálculo de las denominadas “Métricas Alternativas o Sociales”, podemos destacar a fecha 2025-12-22:

  • La utilización de esta aportación en marcadores, bifurcaciones de código, añadidos a listas de favoritos para una lectura recurrente, así como visualizaciones generales, indica que alguien está usando la publicación como base de su trabajo actual. Esto puede ser un indicador destacado de futuras citas más formales y académicas. Tal afirmación es avalada por el resultado del indicador “Capture” que arroja un total de: 54 (PlumX).

Es fundamental presentar evidencias que respalden la plena alineación con los principios y directrices institucionales en torno a la Ciencia Abierta y la Conservación y Difusión del Patrimonio Intelectual. Un claro ejemplo de ello es:

  • El trabajo se ha enviado a una revista cuya política editorial permite la publicación en abierto Open Access.
[+]

Análisis de liderazgo de los autores institucionales

Este trabajo se ha realizado con colaboración internacional, concretamente con investigadores de: United States of America.

[+]