Construction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilities

Publicated to: Buildings. 14 (3): 655- - 2024-03-01 14(3), DOI: 10.3390/buildings14030655

Authors:

Gomez-Villarino, Maria Teresa; Barbero-Barrera, Maria del Mar; Canas, Ignacio; Ramos-Sanz, Alba; Baptista, Fatima; Mazarron, Fernando R
[+]

Affiliations

Consejo Nacl Invest Cient & Tecn CONICET - Author
Univ Evora, MED Medmediterranean Inst Agr, Environm & Dev & CHANGE Global Change & Sustainabi, Dept Engn Rural Escola Ciencias & Tecnol - Author
Univ Politecn Madrid, Escuela Tecn Super Arquitectura, Dept Construct & Technol Architecture - Author
Univ Politecn Madrid, Escuela Tecn Super Ingn Agron Alimentaria & Biosis, Dept Agroforestry Engn - Author
See more

Abstract

The wine industry requires a considerable amount of energy, with an important fraction corresponding to the cooling and ventilation of above-ground aging warehouses. The large investments made in aging facilities can compromise the viability and competitiveness of wineries if their design is not optimized. The objective of this study was to provide guidance for the efficient design of new above-ground warehouses. To this end, multiple construction solutions (structure, envelopes, levels of integration, etc.) were characterized, and their costs and the resulting interior environments were analyzed. The results offer a comprehensive view of potential construction solutions and benchmark price ranges for viable and profitable designs. With a total cost of 300 EUR/m2, an average damping of 98% per day can be achieved. Increasing the costs does not imply better effectiveness. A double enclosure with internal insulation-with or without an air chamber-can achieve excellent results. Greater integration as a result of several enclosures being in contact with other rooms and/or the terrain allows for a high effectiveness to be achieved without air conditioning. Perimeter glazing and ventilation holes can reduce the effectiveness of the construction, resulting in greater instability and a lower damping capacity.
[+]

Keywords

Above groundsAbove-ground warehouseAgingAirAir conditioningBuilding designConstructionConstruction solutionsCostCost behaviorDampingEnclosuresEnergyIndustry, innovation and infrastructureInertiaInvestmentsProvide guidancesRoomsSolution behaviorThermal behavioursWarehousesWineWine industryWine-aging

Quality index

Bibliometric impact. Analysis of the contribution and dissemination channel

The work has been published in the journal Buildings due to its progression and the good impact it has achieved in recent years, according to the agency Scopus (SJR), it has become a reference in its field. In the year of publication of the work, 2024 there are still no calculated indicators, but in 2023, it was in position , thus managing to position itself as a Q1 (Primer Cuartil), in the category Architecture. Notably, the journal is positioned above the 90th percentile.

Independientemente del impacto esperado determinado por el canal de difusión, es importante destacar el impacto real observado de la propia aportación.

Según las diferentes agencias de indexación, el número de citas acumuladas por esta publicación hasta la fecha 2026-04-27:

  • WoS: 2
  • Scopus: 2
[+]

Impact and social visibility

From the perspective of influence or social adoption, and based on metrics associated with mentions and interactions provided by agencies specializing in calculating the so-called "Alternative or Social Metrics," we can highlight as of 2026-04-27:

  • The use of this contribution in bookmarks, code forks, additions to favorite lists for recurrent reading, as well as general views, indicates that someone is using the publication as a basis for their current work. This may be a notable indicator of future more formal and academic citations. This claim is supported by the result of the "Capture" indicator, which yields a total of: 4 (PlumX).

With a more dissemination-oriented intent and targeting more general audiences, we can observe other more global scores such as:

    It is essential to present evidence supporting full alignment with institutional principles and guidelines on Open Science and the Conservation and Dissemination of Intellectual Heritage. A clear example of this is:

    • The work has been submitted to a journal whose editorial policy allows open Open Access publication.
    • Assignment of a Handle/URN as an identifier within the deposit in the Institutional Repository: https://oa.upm.es/90705/

    As a result of the publication of the work in the institutional repository, statistical usage data has been obtained that reflects its impact. In terms of dissemination, we can state that, as of

    • Views: 133
    • Downloads: 21
    Continuing with the social impact of the work, it is important to emphasize that, due to its content, it can be assigned to the area of interest of ODS 9 - Industry, innovation and infrastructure, with a probability of 44% according to the mBERT algorithm developed by Aurora University.
    [+]

    Leadership analysis of institutional authors

    This work has been carried out with international collaboration, specifically with researchers from: Argentina; Portugal.

    There is a significant leadership presence as some of the institution’s authors appear as the first or last signer, detailed as follows: First Author (GOMEZ VILLARINO, MARIA TERESA) and Last Author (RUIZ MAZARRON, FERNANDO).

    the author responsible for correspondence tasks has been RUIZ MAZARRON, FERNANDO.

    [+]

    Project objectives

    La aportación persigue los siguientes objetivos: analizar múltiples soluciones constructivas para bodegas de envejecimiento de vino sobre el suelo; evaluar los costos asociados a dichas soluciones y su impacto en el comportamiento térmico interior; caracterizar la efectividad térmica en función de diferentes configuraciones, incluyendo doble cerramiento con aislamiento interno; determinar la relación costo-efectividad para optimizar el diseño sin incrementar gastos innecesarios; y examinar el efecto de la integración con otras estancias y el terreno en la eficiencia térmica, así como el impacto negativo de elementos como acristalamientos perimetrales y ventilaciones en la estabilidad térmica y capacidad de amortiguamiento.
    [+]

    Most relevant results

    El estudio analiza soluciones constructivas para bodegas de envejecimiento de vino sobre suelo, evaluando costos y comportamiento térmico. Los resultados más relevantes son: (1) se logra una amortiguación térmica promedio del 98% diario con un coste total de 300 EUR/m²; (2) aumentar el coste no garantiza mayor efectividad térmica; (3) una doble envolvente con aislamiento interno, con o sin cámara de aire, ofrece excelentes resultados; (4) la integración de varias envolventes en contacto con otras estancias o el terreno permite alta efectividad sin necesidad de aire acondicionado; (5) la presencia de acristalamientos perimetrales y orificios de ventilación disminuye la estabilidad térmica y la capacidad de amortiguación.
    [+]