
Indexat a
Llicència i ús

Grant support
The study presented in this paper has received no particular funding, but the experimental infrastructure is a result of previous projects fun- ded by the Spanish Research Agency (Ref. BIA2012-30998 and BIA2016-74960-R AEI/FEDER, UE) .
Anàlisi d'autories institucional
Ulzurrun, Gonzalo S DAutor o coautorZanuy, CarlosAutor (correspondència)Dynamic shear force-bending moment interaction diagrams in RC beams under impact
Publicat a:Engineering Structures. 308 118021- - 2024-06-01 308(), DOI: 10.1016/j.engstruct.2024.118021
Autors: Ulzurrun, GSD; Zanuy, C
Afiliacions
Resum
Civil structures and buildings may be subjected to accidental impact load scenarios to which the response is still a research subject. Impact failure mode and resistance of concrete structures have shown to be rather different from those under quasi-static loading, due to the influence of strain-rate modification of material properties, development of inertia forces leading to variable sectional forces' distributions and local damage mechanisms. A high sensitivity to develop shear-related failures of reinforced concrete beams under impact loading has been observed experimentally, with a complex shear-bending interaction difficult to be modelled numerical and analytically. Shear force-bending moment (M-V) interaction diagrams have been traditionally employed to provide the combination of sectional forces leading to failure. Thus, the availability of such diagrams for impact scenarios would be very useful for the engineering practice. In the present paper, an experimental investigation is presented to analyze the impact resistance of reinforced concrete beams with different span-to-depth ratios in order to determine possible envelope M-V interaction curves in impact regime. Sectional forces are tracked with the help of Digital Image Correlation (DIC) supported with High-Speed Video (HSV). Impact tests have covered beam specimens with and without shear reinforcement to understand the different failure modes. Envelope interaction diagrams are proposed taking into account the curvature rate from the experiments, which allows considering the particular strain-rate conditions of the tests.
Paraules clau
Indicis de qualitat
Impacte bibliomètric. Anàlisi de la contribució i canal de difusió
El treball ha estat publicat a la revista Engineering Structures a causa de la seva progressió i el bon impacte que ha aconseguit en els últims anys, segons l'agència WoS (JCR), s'ha convertit en una referència en el seu camp. A l'any de publicació del treball, 2024 encara no hi ha indicis calculats, però el 2023, es trobava a la posició 18/182, aconseguint així situar-se com a revista Q1 (Primer Cuartil), en la categoria Engineering, Civil. Destacable, igualment, el fet que la revista està posicionada per sobre del Percentil 90.
Independentment de l'impacte esperat determinat pel canal de difusió, és important destacar l'impacte real observat de la pròpia aportació.
Segons les diferents agències d'indexació, el nombre de citacions acumulades per aquesta publicació fins a la data 2025-06-14:
- WoS: 2
- Scopus: 3
Impacte i visibilitat social
Anàlisi del lideratge dels autors institucionals
Hi ha un lideratge significatiu, ja que alguns dels autors pertanyents a la institució apareixen com a primer o últim signant, es pot apreciar en el detall: Primer Autor (SANZ DIEZ DE ULZURRUN CASALS, GONZALO) i Últim Autor (ZANUY SANCHEZ, CARLOS).
l'autor responsable d'establir les tasques de correspondència ha estat ZANUY SANCHEZ, CARLOS.